High

Blind SQL Injection via GridFieldSortableHeader

  • Disclosed: 22.11.2022
  • Updated: 11.10.2026 10:22

Gridfield state is vulnerable to SQL injections. The vast majority of Gridfields in Silverstripe CMS are affected by this vulnerability.

An attacker with CMS access could execute an arbitrary SQL statement by adding an SQL payload in some parts of the GridField state.

Affected software

Click a technology to see all vulnerabilities affecting it.

PlatformPackageVulnerable versionsFixed in
Composer package silverstripe/framework >= 4.0.0, < 4.10.11, >= 4.11.0, < 4.11.14 4.10.11, 4.11.14

References

CVSS score 8.8/10
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness (CWE)
CWE-89
Platform
Composer
Package
silverstripe/framework
Disclosed
22.11.2022
Updated
11.10.2026 10:22

Sources and licenses

OSV / GitHub Advisory Database - GHSA-rr8h-f97q-8p9c - CC BY 4.0

Vulnerability history: silverstripe/framework

All published vulnerabilities of this package (Composer package), newest first. Shows whether this is a one-off slip or a package that needs watching.

All (93) in the archive
Total entries
93
First → latest
11.2019 08.2026
Without a fix
1
Exploited in attacks
0

Severity breakdown

  • Critical 3
  • High 13
  • Medium 69
  • Low 8

Disclosures per year

  1. 2019: 5
  2. 2020: 2
  3. 2021: 0
  4. 2022: 23
  5. 2023: 3
  6. 2024: 53
  7. 2025: 6
  8. 2026: 1
Severity:
  1. High · 8.8 ghsa-265q-222x-52m6 >= 4.0.0-rc1, < 4.0.6, >= 4.1.0-rc1, < 4.1.4, >= 4.2.0-rc1, < 4.2.3 4.0.6, 4.1.4, 4.2.3
  2. High · 7.5 ghsa-cwgq-83w5-8jfq >= 4.0.0-rc1, < 4.0.5, >= 4.1.0-rc1, < 4.1.3, >= 4.2.0-rc1, < 4.2.2 4.0.5, 4.1.3, 4.2.2
  3. High · 8.8 ghsa-vcg6-8fxc-x5cq >= 3.6.5-rc1, < 3.6.6, >= 4.0.3-rc1, < 4.0.4, >= 4.1.0-rc1, < 4.1.1 3.6.6, 4.0.4, 4.1.1
  4. High · 7.5 ghsa-vgxh-x8jv-hmff >= 4.0.3-rc1, < 4.0.4, >= 4.1.0-rc1, < 4.1.1 4.0.4, 4.1.1
  5. High · 7.5 ghsa-m5q3-mvcr-gc5m >= 4.0.0-rc1, < 4.0.4, >= 4.1.0-rc1, < 4.1.1 4.0.4, 4.1.1
  6. High · 8.8 ghsa-xx4r-5265-48j6 >= 3.5.0-rc1, < 3.5.6, >= 3.6.0-rc1, < 3.6.3, >= 4.0.0-rc1, < 4.0.1 3.5.6, 3.6.3, 4.0.1
  7. High · 8.0 ghsa-mqjc-x563-c9q8 >= 3.5.0-rc1, < 3.5.6, >= 3.6.0-rc1, < 3.6.3, >= 4.0.0-rc1, < 4.0.1 3.5.6, 3.6.3, 4.0.1
  8. High ghsa-7m2v-x7rg-5hm5 >= 3.5.0-rc1, < 3.5.5, >= 3.6.0-rc1, < 3.6.2 3.5.5, 3.6.2
  9. High · 7.5 ghsa-4qx8-j9vh-2628 >= 3.5.0-rc1, < 3.5.6, >= 3.6.0-rc1, < 3.6.3 3.5.6, 3.6.3
  10. Critical · 9.1 ghsa-8v6m-7f5v-hhx6 >= 3.1.18, < 3.1.19, >= 3.2.3, < 3.2.4, >= 3.3.1, < 3.3.2 3.1.19, 3.2.4, 3.3.2
  11. High · 7.2 ghsa-25gq-jvx2-vg9x >= 3.1.0, < 3.1.13 3.1.13
  12. Blind SQL Injection via GridFieldSortableHeader this entry
    High · 8.8 CVE-2022-38148 >= 4.0.0, < 4.10.11, >= 4.11.0, < 4.11.14 4.10.11, 4.11.14
  13. High · 7.5 CVE-2020-6164 >= 4.0.0, < 4.4.7, >= 4.5.0, < 4.5.4 4.4.7, 4.5.4
  14. High · 7.5 CVE-2020-9280 >= 4.0.0, < 4.4.6 4.4.6
  15. Critical · 9.8 CVE-2019-5715 >= 3.0.0, < 3.6.7, >= 4.0.0, < 4.0.7, >= 3.7.0, < 3.7.3, >= 4.1.0, < 4.1.5, >= 4.2.0, < 4.2.4, >= 4.3.0, < 4.3.1 3.6.7, 4.0.7, 3.7.3, 4.1.5, 4.2.4, 4.3.1
  16. Critical · 9.8 CVE-2019-12204 >= 4.1.0, < 4.3.5 4.3.5

Know which vulnerabilities affect your application

With the DockRay integration and software inventory enabled, DockRay checks reported component versions against known vulnerabilities and notifies you about confirmed matches. Coverage depends on the supported technology and available advisory data.

Connect your application
DockRay newsletter

Application security in your inbox

Important vulnerabilities, actionable guidance and practical advice for your applications. Choose your technologies and follow what matters to your project.

  • A daily digest of new vulnerabilities, critical ones included.
  • Notifications about important updates.
  • Practical advice on application security and monitoring.

Leave empty to receive updates for every technology.

Free to subscribe. Unsubscribe with one click in any email.