Systeminformation has command injection vulnerability in getWindowsIEEE8021x (SSID)
Summary
The SSID is not sanitized when before it is passed as a parameter to cmd.exe in the getWindowsIEEE8021x function. This means that malicious content in the SSID can be executed as OS commands.
Details
I have exploited this vulnerability in a Windows service using version 5.22.11 of the module, to escalate privileges (in an environment where I am authorized to do so). However, as far as I can see from the code, it is still present in master branch at time of writing, on line 403/404 of network.js.
The SSID is obtained from netsh wlan show interface ... in getWindowsWirelessIfaceSSID, and then passed to cmd.exe /d /s /c "netsh wlan show profiles ... in getWindowsIEEE8021x, without sanitization.
PoC
First, the command injection payload should be included in the connected Wi-Fi SSID. For example create hotspot on mobile phone or other laptop, set SSID to payload, connect to it with victim Windows system. Two example SSID's to demonstrate exploitation are below.
Demonstration to run ping command indefinitely:
a" | ping /t 127.0.0.1 &
Run executable with privileges of the user in which vulnerable function is executed. Chosen executable should should be placed in (assuming system drive is C): C:\a\a.exe.
a" | %SystemDrive%\a\a.exe &
Then, the vulnerable function can be executed on the victim system, for example, using:
const si = require('systeminformation');
si.networkInterfaces((net) => { console.log(net) });
Now the chosen command, PING.exe or a.exe will be run through the cmd.exe command line.
Impact
This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation.
Software afectado
Haz clic en una tecnología para ver todas sus vulnerabilidades.
| Plataforma | Paquete | Versiones vulnerables | Corregida en |
|---|---|---|---|
| Paquete de npm | systeminformation | < 5.23.7 | 5.23.7 |
Referencias
- Vector CVSS
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H- Debilidad (CWE)
CWE-94- Plataforma
- npm
- Paquete
systeminformation- Publicada
- 20.12.2024
- Actualizado
- 11.10.2026 10:22
Fuentes y licencias
OSV / GitHub Advisory Database - GHSA-cvv5-9h9w-qp2m - CC BY 4.0
Historial de vulnerabilidades: systeminformation
Todas las vulnerabilidades publicadas de este paquete (Paquete de npm), de la más reciente a la más antigua. Muestra si es un fallo aislado o un paquete que hay que vigilar.
- Entradas en total
- 14
- Primera → última
- 10.2020 07.2026
- Sin corrección
- 0
- Explotada en ataques
- 1
Distribución por gravedad
- Crítica 1
- Alta 10
- Media 3
Divulgaciones por año
- 2020: 4
- 2021: 2
- 2022: 1
- 2023: 1
- 2024: 1
- 2025: 1
- 2026: 4
-
Systeminformation has command injection vulnerability in getWindowsIEEE8021x (SSID) esta entrada
Identifica las vulnerabilidades de tu aplicación
Con la integración de DockRay y el inventario de software activado, DockRay compara las versiones notificadas de los componentes con las vulnerabilidades conocidas y avisa de las coincidencias confirmadas. La cobertura depende de la tecnología compatible y de los avisos disponibles.